Rotate the map and get as much liquid to the end without it getting vaporized by yellow pads. Flowjo 10 0 for mac free download. A liquid flow meter from Grainger can help easily monitor liquid flow rates for water, fuels, viscous fluids and more. Check out this selection to find flow meters that can handle petroleum products, nonpotable water and compatible chemicals for fuel-dispensing pumps and industrial flow measurement. 0.4 2.61 0.11 491 325 232 200 174 0.5 3.27 0.17 742 491 350 302 264. Flow of Water in Pipes 0.25 Inch Diameter Pipe Headloss in Feet per 1,000 Feet, for C=. Flow Switches for Water, Oil, Air, and Inert Gas For installation in environments with flammable gases and combustible dust, these flow switches are UL listed for use in hazardous locations.
Calculator
Previous page | Home
Fluid Flow Calculator
by Michael J. Rocchetti PE
Mechanical Engineer
This calculator is used to calculate pipe friction losses for straight piping handling water and water with varying percentages of ethylene glycol. The calculator uses an algorithm developed from the basic principles of fluid mechanics. The program is based on the Darcy-Weisbach equation, the Colebrook equation, and the Moody equation. The program is intended for use only on straight piping. The program does not include pressure losses due to elevation differences, or flow through fittings.
This calculator allows you to input the fluid type, the fluid temperature, the flow rate, the pipe size, pipe length, and pipe material. Winaday no deposit bonus codes 2017. The calculator then determines the velocity, the Reynolds number, the Moody friction factor, the pipe friction factor (from the Colebrook equation), the pipe head loss, and the pipe friction loss in PSI. This calculator is intended for use on systems handling water and water with varying percentages of ethylene glycol. Red giant primatte keyer v5 1 9.
Please note that this method works for turbulent flow situations where the Reynolds Number is greater than 3000. Textual 7 0 9 – lightweight irc client. If you find that your Reynolds number is less than 3000, you should revise your input parameters (increase the flow rate and/or reduce the pipe size).
Additional Design Criteria: If your piping is being used in an open loop system, flow velocities should be in the range of 5 to 10 ft/sec. For closed loop piping systems, you should use a 4 ft/sec limit for piping of 2' or less. For larger pipe sizes, use a limit of 4 FT of head loss per 100 FT of pipe.
References:
- Fluid Mechanics and its applications by James W Murdock, PE
Houghton Mifflin Co. - Heating Ventilating and Air Conditioning Analysis and Design
by Faye C. McQuiston and Jerald D. Parker
John Wiley & Sons. - Flow of Fluids Through Valves, Fittings, and Pipe
Technical Paper No. 410
The Crane Company - ASHRAE Fundamentals 1993
The American Society of Heating Refrigerating and Air Conditioning Engineers
Flow includes Flow Transmitters, Flow Sensors, Flowmeters, Sight Flow Indicators and Water Meters. Mass Flowmeters, Controllers, Flow Indicators and Controllers are ideal for measurement of flow rates. Flow Switches come as paddle, thermal, piezo, and shuttle/piston.
- Mass Flowmeters and Controllers
- Series VF
- Series WM2 & WMT2
- Series VF
- Series RM
Pressure: Q2 = Q1 x √((P1 x T2)/(P2 x T1))
Where:
Q1 = Observed Flowmeter Reading
Q2 = Standard Flow Corrected for Specific Gravity
P1 = Actual Pressure (14.7 psia + Gage Pressure)
P2 = Standard Pressure (14.7 psia, which is 0 psig)
T1 = Actual Temperature (460 R + Temp °F)
T2 = Standard Temperature (530 R, which is 70°F)